In the MS-LaserLab: Analytics of Biomolecular Interactions, we use a wide variety of research instruments, listed below. Our main instruments include modified mass spectrometers for optical laser access, and instrumentation for native MS. However, within the Division of BioAnalytical Chemistry, we also have access to a number of other mass spectrometers, LC systems, plate readers, and general chemistry equipment (shakers, centrifuges etc).
Our mass spectrometers with optical access
We proudly present: the Photo-Synapt
We have developed the Photo-Synapt, a novel, multidimensional spectrometer that integrates ion mobility mass spectrometry with infrared (IR) action spectroscopy within a single experiment. It can select and isolate individual oligomers by mass, charge, size, and shape and provide unique molecular fingerprints for each oligomer. It’s name?
Probing Higher-Order Transient Oligomers = PHOTO-Synapt 🙂

Orbitrap QE+ with cryo add-on for laser spectroscopy
An Orbitrap QE+ was modified to allow ions after the HCD cell to go into a cold trap (down to 35K: ICE-Orbi), where they are interrogated by our UV and/or IR lasers, and detected again in the Orbitrap mass analyzer.
Incredibly Cold Experiments: ICE-Orbi.


Ion trap (Amazon speed ETD) with optical access
This linear ion trap, named FIRE-trap, has optical access to allow for UVPD and IRMPD experiments, complementing the ETD and CID fragmentation options. This allows for complex schemes using different fragmentation methods in the same measurement.
Fragmenting by Impact, Radiation, and Electrons: FIREtrap.


Other instruments in our lab
Nanotip fabrication
In our lab we have a P-1000 puller to create nanotips and a P-2000 laser puller to create nanopips, both for native MS. A sputter coater is used to coat the pulled tips.

Droplet microfluidics
Equipment to do droplet microfluidics is present, such as microscopes and syringe pumps.


Other mass spectrometers within the Division of BioAnalytical Chemistry
timsTOF Pro2
The timsTOF Pro 2 combines high-resolution Q-TOF mass spectrometry with trapped ion mobility spectrometry (TIMS), providing an additional dimension of separation for complex samples. With our custom built nano-ESI sources they are much used for native studies.



LCT Premier
The LCT Premier, the oldest mass spectrometer we have around, is mainly used to test newly made nanotips and nanopipettes and test droplet microfluidics.

Exploris 480
Powerful high resolution instrument, equipped with FAIMS and nano-ESI. Sometimes hyphenated with nanoLC or CE.

Q-ToFs
We have multiple Q-ToFs: Xevo G2-XS, Impact II, ZenoToF, and MaXis, which can be equipped with LC systems or nano-ESI.